ENSY AHU 300 CEILING FILTER SET (240x140x94)

  • Delivery: 4-8 days.
€24.49

ENSY AHU 300 CEILING Filter Set (240x140x94) includes two F7 filters (ePM1 70%) for complete air filtration in ENSY AHU 300 CEILING recuperators. Made in Lithuania with moisture-resistant frames and DEEP PLEAT technology for stable airflow and efficient particle capture.

Fast EU delivery. Perfect fit for ENSY AHU 300 CEILING units.

Delivery: 4-8 days.
Filtrai1.lt
Reference
K00117

Date sheet

Dimensions (mm)
240x140x94
The set includes:
Filters - 2 pcs.
Delivery of goods
Delivery cost is calculated at checkout based on your country.
model
AHU 300 CEILING

Buy ENSY AHU 300 CEILING Filter Set (240x140x94) online at filters1.eu. This complete replacement filter set includes two F7 filters designed for reliable filtration in ENSY AHU 300 CEILING ventilation units, ensuring cleaner indoor air and optimal system performance across EU homes and facilities.

What This Filter Set Does

This filter set is designed for ENSY AHU 300 CEILING heat recovery ventilation units. The set contains two F7 class filters that work together to filter both incoming fresh air and outgoing exhaust air. These compatible replacement filters maintain efficient air filtration while protecting your recuperator from dust, pollen, and fine particulates. The F7+F7 configuration provides consistent high-level filtration for both air streams.

Understanding F7 Filter Performance

The F7 filter class (also known as ePM1 70% under ISO 16890) captures fine particles effectively:

  • F7 filters capture fine dust, pollen, mold spores, and particles down to PM1 size, providing excellent indoor air quality
  • Recommended for: homes in urban areas, environments with higher pollution levels, or where occupants have allergies or respiratory sensitivities
  • Filtration efficiency: ePM1 70% means these filters capture at least 70% of fine particulate matter in the PM1 range

The F7+F7 set is ideal for maintaining high air quality standards throughout the year.

Product Specifications

  • Compatible model: ENSY AHU 300 CEILING
  • Dimensions: 240x140x94 mm
  • Set contents: 2 filters (F7+F7)
  • Filter class: F7 (ePM1 70%)
  • Country of origin: Lithuania
  • Frame material: Moisture-resistant cardboard
  • Certifications: ISO 16890, EN 779:2012, VDI 6022, DIN 53438

Why Choose These Filters

  • Precise fit for ENSY AHU 300 CEILING units
  • Complete set with both filters included
  • High F7 filtration performance for cleaner air
  • Moisture-resistant construction for long-term durability
  • Large filtering surface area for stable airflow
  • Manufactured to European hygiene and safety standards
  • Fast EU delivery from filters1.eu

DEEP PLEAT Technology

These filters feature DEEP PLEAT technology, which increases the effective filtration surface area within the same compact frame dimensions. This design approach delivers multiple performance benefits for your ventilation system.

  • Larger surface area per filter
  • Consistent airflow throughout service life
  • Effective particle capture
  • Extended operational lifespan

ECO Green Materials

These filters are made using ECO Green materials, incorporating recycled and sustainable components without compromising filtration performance. The moisture-resistant cardboard frame provides structural integrity while supporting a more environmentally conscious approach to indoor air quality management. This practical sustainability focus ensures reliable performance alongside responsible material choices.

Recommended Replacement Interval

Replace your ENSY AHU 300 CEILING filters 2 to 3 times per year, depending on local air quality and system usage. Regular replacement maintains clean indoor air, protects consistent airflow through the unit, and reduces strain on the recuperator fan and heat exchanger components.

Frequently Asked Questions

How often should I replace these filters?

Replace filters 2 to 3 times per year for optimal performance and air quality.

What is the difference between F7 and other filter classes?

F7 filters capture fine particles including PM1, offering higher filtration efficiency than M5 or G4 classes.

Are these filters compatible with my ENSY AHU 300 CEILING unit?

Yes, these filters are designed specifically for ENSY AHU 300 CEILING recuperators with 240x140x94 mm dimensions.

How many filters are included in the set?

The set includes two F7 filters for complete replacement of both air streams.

Are these original or compatible replacement filters?

These are high-quality compatible replacement filters manufactured to meet or exceed original specifications.

Browse our complete range of ENSY HRV filters or explore our full selection of recuperator filters for various ventilation system brands and models across the EU market.

Buy ENSY AHU 300 CEILING Filter Set (240x140x94) online today. Fast EU delivery ensures your ventilation system stays protected with minimal downtime.

Reviews

Write your review

ENSY AHU 300 CEILING FILTER SET (240x140x94)

ENSY AHU 300 CEILING Filter Set (240x140x94) includes two F7 filters (ePM1 70%) for complete air filtration in ENSY AHU 300 CEILING recuperators. Made in Lithuania with moisture-resistant frames and DEEP PLEAT technology for stable airflow and efficient particle capture.

Fast EU delivery. Perfect fit for ENSY AHU 300 CEILING units.

Filter Type / EN 779 ISO 16890 >10 µm PM10 PM2.5 PM1 Gas/LOI Typical Pollutants
G1 ISO Coarse ~40% <10% ~0% ~0% Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc.
G2 ISO Coarse ~50% <15% ~0% ~0% Sawdust, hair, large fabric shreds, paint chips, surface rust particles.
G3 ISO Coarse ~60% <25% ~5% ~0% Larger household dust, lint, animal hair, some airborne pollen.
G4 ISO Coarse 65-75% 25-35% 10-15% <5% Larger pollen grains, soil and sand impurities, textile fibers.
M5 ISO ePM10 ≥50% ~80% 50–65% 20–30% 10–15% Most pollen, mold spores, pet dander, typical house dust.
M6 ISO ePM10 (60–80%) ~90% 65–80% 30–45% 15–25% Construction material dust, concrete and cement powders, ash and other friable material particles.
F7 ISO ePM2.5 (50–65%) >90% 75–90% 50–65% 30–45% Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke.
F8 ISO ePM2.5 (65–80%) >95% 85-95% 65–80% 45-60% Fine fungal spores, airborne pollutant aerosols and other fine solid particles.
F9 ISO ePM1 (80-95 %) >95% >95% >90% 80-95% Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere.

Buy ENSY AHU 300 CEILING Filter Set (240x140x94) online at filters1.eu. This complete replacement filter set includes two F7 filters designed for reliable filtration in ENSY AHU 300 CEILING ventilation units, ensuring cleaner indoor air and optimal system performance across EU homes and facilities.

What This Filter Set Does

This filter set is designed for ENSY AHU 300 CEILING heat recovery ventilation units. The set contains two F7 class filters that work together to filter both incoming fresh air and outgoing exhaust air. These compatible replacement filters maintain efficient air filtration while protecting your recuperator from dust, pollen, and fine particulates. The F7+F7 configuration provides consistent high-level filtration for both air streams.

Understanding F7 Filter Performance

The F7 filter class (also known as ePM1 70% under ISO 16890) captures fine particles effectively:

  • F7 filters capture fine dust, pollen, mold spores, and particles down to PM1 size, providing excellent indoor air quality
  • Recommended for: homes in urban areas, environments with higher pollution levels, or where occupants have allergies or respiratory sensitivities
  • Filtration efficiency: ePM1 70% means these filters capture at least 70% of fine particulate matter in the PM1 range

The F7+F7 set is ideal for maintaining high air quality standards throughout the year.

Product Specifications

  • Compatible model: ENSY AHU 300 CEILING
  • Dimensions: 240x140x94 mm
  • Set contents: 2 filters (F7+F7)
  • Filter class: F7 (ePM1 70%)
  • Country of origin: Lithuania
  • Frame material: Moisture-resistant cardboard
  • Certifications: ISO 16890, EN 779:2012, VDI 6022, DIN 53438

Why Choose These Filters

  • Precise fit for ENSY AHU 300 CEILING units
  • Complete set with both filters included
  • High F7 filtration performance for cleaner air
  • Moisture-resistant construction for long-term durability
  • Large filtering surface area for stable airflow
  • Manufactured to European hygiene and safety standards
  • Fast EU delivery from filters1.eu

DEEP PLEAT Technology

These filters feature DEEP PLEAT technology, which increases the effective filtration surface area within the same compact frame dimensions. This design approach delivers multiple performance benefits for your ventilation system.

  • Larger surface area per filter
  • Consistent airflow throughout service life
  • Effective particle capture
  • Extended operational lifespan

ECO Green Materials

These filters are made using ECO Green materials, incorporating recycled and sustainable components without compromising filtration performance. The moisture-resistant cardboard frame provides structural integrity while supporting a more environmentally conscious approach to indoor air quality management. This practical sustainability focus ensures reliable performance alongside responsible material choices.

Recommended Replacement Interval

Replace your ENSY AHU 300 CEILING filters 2 to 3 times per year, depending on local air quality and system usage. Regular replacement maintains clean indoor air, protects consistent airflow through the unit, and reduces strain on the recuperator fan and heat exchanger components.

Frequently Asked Questions

How often should I replace these filters?

Replace filters 2 to 3 times per year for optimal performance and air quality.

What is the difference between F7 and other filter classes?

F7 filters capture fine particles including PM1, offering higher filtration efficiency than M5 or G4 classes.

Are these filters compatible with my ENSY AHU 300 CEILING unit?

Yes, these filters are designed specifically for ENSY AHU 300 CEILING recuperators with 240x140x94 mm dimensions.

How many filters are included in the set?

The set includes two F7 filters for complete replacement of both air streams.

Are these original or compatible replacement filters?

These are high-quality compatible replacement filters manufactured to meet or exceed original specifications.

Browse our complete range of ENSY HRV filters or explore our full selection of recuperator filters for various ventilation system brands and models across the EU market.

Buy ENSY AHU 300 CEILING Filter Set (240x140x94) online today. Fast EU delivery ensures your ventilation system stays protected with minimal downtime.

Reviews

Write your review

ENSY AHU 300 CEILING FILTER SET (240x140x94)

ENSY AHU 300 CEILING Filter Set (240x140x94) includes two F7 filters (ePM1 70%) for complete air filtration in ENSY AHU 300 CEILING recuperators. Made in Lithuania with moisture-resistant frames and DEEP PLEAT technology for stable airflow and efficient particle capture.

Fast EU delivery. Perfect fit for ENSY AHU 300 CEILING units.

Filter Type / EN 779 ISO 16890 >10 µm PM10 PM2.5 PM1 Gas/LOI Typical Pollutants
G1 ISO Coarse ~40% <10% ~0% ~0% Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc.
G2 ISO Coarse ~50% <15% ~0% ~0% Sawdust, hair, large fabric shreds, paint chips, surface rust particles.
G3 ISO Coarse ~60% <25% ~5% ~0% Larger household dust, lint, animal hair, some airborne pollen.
G4 ISO Coarse 65-75% 25-35% 10-15% <5% Larger pollen grains, soil and sand impurities, textile fibers.
M5 ISO ePM10 ≥50% ~80% 50–65% 20–30% 10–15% Most pollen, mold spores, pet dander, typical house dust.
M6 ISO ePM10 (60–80%) ~90% 65–80% 30–45% 15–25% Construction material dust, concrete and cement powders, ash and other friable material particles.
F7 ISO ePM2.5 (50–65%) >90% 75–90% 50–65% 30–45% Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke.
F8 ISO ePM2.5 (65–80%) >95% 85-95% 65–80% 45-60% Fine fungal spores, airborne pollutant aerosols and other fine solid particles.
F9 ISO ePM1 (80-95 %) >95% >95% >90% 80-95% Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere.