- Delivery: 15-25 days.
ENSY AHU 200 Filter Set (280x120x94) includes two F7 (ePM1 70%) filters for ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM recuperators. Features moisture-resistant cardboard frame, DEEP PLEAT technology, and ECO Green materials for reliable fine particle filtration in residential and commercial ventilation systems.
Fast EU delivery. Perfect fit for ENSY AHU 200 series.
Date sheet
Buy ENSY AHU 200 Filter Set (280x120x94) online. Premium F7+F7 replacement filters designed for ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM recuperators, offering high-efficiency filtration with fast EU delivery.
This complete filter set is specifically designed for ENSY AHU 200 series heat recovery ventilation units. The set includes two F7 class filters (ePM1 70%) that work together to filter both incoming supply air and outgoing extract air. Compatible with ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM models, these filters provide reliable performance for residential and commercial ventilation systems across the EU.
Understanding filter classes helps you choose the right filtration level for your needs:
This F7+F7 configuration offers enhanced protection against fine particles, making it ideal for urban environments, allergy sufferers, and areas with moderate air pollution. Choose F7 filters when indoor air quality is a priority.
Our DEEP PLEAT manufacturing process creates filters with maximized surface area, ensuring efficient particle capture while maintaining stable airflow through your ENSY recuperator system.
These ENSY AHU 200 replacement filters feature ECO Green construction, using recycled and sustainable materials where possible. Our practical approach to sustainability delivers reliable filtration performance while minimizing environmental impact through responsible material selection and efficient manufacturing processes.
Replace your ENSY AHU 200 filters 2 to 3 times per year to maintain optimal performance. Regular replacement ensures cleaner indoor air quality, protects consistent airflow through your ventilation system, and reduces strain on your HRV unit. More frequent changes may be needed in dusty environments or high-usage settings.
Replace filters 2 to 3 times per year, or more frequently in dusty conditions.
F7 filters capture finer particles including pollen and combustion particles, while M5 filters capture larger dust particles.
Yes, these filters fit ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM models perfectly.
The set includes 2 filters, one for supply air and one for extract air.
These are high-quality compatible replacement filters designed to match original specifications.
Browse our complete range of ENSY HRV filters or explore all available recuperator filters for various ventilation system brands across Europe.
Buy ENSY AHU 200 Filter Set (280x120x94) online. Fast EU delivery ensures your ventilation system maintains peak performance.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |
Buy ENSY AHU 200 Filter Set (280x120x94) online. Premium F7+F7 replacement filters designed for ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM recuperators, offering high-efficiency filtration with fast EU delivery.
This complete filter set is specifically designed for ENSY AHU 200 series heat recovery ventilation units. The set includes two F7 class filters (ePM1 70%) that work together to filter both incoming supply air and outgoing extract air. Compatible with ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM models, these filters provide reliable performance for residential and commercial ventilation systems across the EU.
Understanding filter classes helps you choose the right filtration level for your needs:
This F7+F7 configuration offers enhanced protection against fine particles, making it ideal for urban environments, allergy sufferers, and areas with moderate air pollution. Choose F7 filters when indoor air quality is a priority.
Our DEEP PLEAT manufacturing process creates filters with maximized surface area, ensuring efficient particle capture while maintaining stable airflow through your ENSY recuperator system.
These ENSY AHU 200 replacement filters feature ECO Green construction, using recycled and sustainable materials where possible. Our practical approach to sustainability delivers reliable filtration performance while minimizing environmental impact through responsible material selection and efficient manufacturing processes.
Replace your ENSY AHU 200 filters 2 to 3 times per year to maintain optimal performance. Regular replacement ensures cleaner indoor air quality, protects consistent airflow through your ventilation system, and reduces strain on your HRV unit. More frequent changes may be needed in dusty environments or high-usage settings.
Replace filters 2 to 3 times per year, or more frequently in dusty conditions.
F7 filters capture finer particles including pollen and combustion particles, while M5 filters capture larger dust particles.
Yes, these filters fit ENSY AHU 200 H/V, AHU 200 KH, and AHU 200 KV_SLIM models perfectly.
The set includes 2 filters, one for supply air and one for extract air.
These are high-quality compatible replacement filters designed to match original specifications.
Browse our complete range of ENSY HRV filters or explore all available recuperator filters for various ventilation system brands across Europe.
Buy ENSY AHU 200 Filter Set (280x120x94) online. Fast EU delivery ensures your ventilation system maintains peak performance.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |