- Delivery: 15-25 days.
Flexit L7X/S7X (VG700) Filter Set (394x223x250/5 + 394x223x20) delivers premium F7+F7 filtration for your heat recovery ventilation system. This complete two-filter replacement set captures ultra-fine particles down to 0.3 micrometers, providing superior indoor air quality protection. Manufactured in Lithuania with moisture-resistant construction and DEEP PLEAT technology for extended service life and stable airflow.
Fast EU delivery. Perfect fit for Flexit L7X/S7X (VG700) recuperators.
Date sheet
Buy Flexit L7X/S7X (VG700) Filter Set (394x223x250/5 + 394x223x20) online. This complete dual-filter replacement set ensures optimal air quality and system performance in your Flexit ventilation unit with fast EU delivery.
This replacement filter set is designed specifically for the Flexit L7X/S7X (VG700) heat recovery ventilation system. The set includes two high-efficiency filters that work together to clean both incoming supply air and extracted exhaust air. Available in the F7+F7 configuration, this set delivers premium filtration performance for residential and commercial installations where superior indoor air quality is required.
Understanding filter efficiency helps you choose the right set for your environment:
Choose the F7+F7 set when indoor air purity is your top priority and you want comprehensive protection against fine particulate matter.
Our Flexit L7X/S7X filter sets feature DEEP PLEAT construction that maximizes filtration surface area within the standard frame dimensions. This advanced pleating method delivers superior performance compared to conventional flat-panel designs.
These Flexit HRV filters are manufactured using ECO Green materials that balance environmental responsibility with filtration performance. The moisture-resistant cardboard frame is recyclable, and the filter media is designed for efficient particle capture without excessive material use. This practical approach to sustainability delivers the air quality you need while minimizing environmental impact.
For optimal performance, replace your Flexit L7X/S7X filters two to three times per year, depending on local air quality and system usage patterns. Regular replacement maintains cleaner indoor air, protects efficient airflow through the ventilation system, and reduces mechanical strain on the HRV unit. If you live in an urban area or near construction sites, consider replacing filters more frequently.
Replace filters every 4 to 6 months, or 2 to 3 times per year based on air quality conditions.
M5 captures particles down to 10 micrometers, while F7 captures ultra-fine particles down to 0.3 micrometers for superior air quality.
Yes, this set is specifically designed for Flexit L7X/S7X (VG700) recuperators with filter dimensions 394x223x250/5 + 394x223x20 mm.
The set includes two filters in the F7+F7 configuration for complete system filtration.
These are high-quality compatible aftermarket replacement filters that meet or exceed original specifications.
Explore our full range of Flexit HRV Filters for other Flexit ventilation models, or browse our complete selection of recuperator filters for all major heat recovery ventilation brands.
Buy Flexit L7X/S7X (VG700) Filter Set (394x223x250/5 + 394x223x20) online today. Ensure optimal air quality in your ventilation system with this precision-engineered replacement filter set.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |
Buy Flexit L7X/S7X (VG700) Filter Set (394x223x250/5 + 394x223x20) online. This complete dual-filter replacement set ensures optimal air quality and system performance in your Flexit ventilation unit with fast EU delivery.
This replacement filter set is designed specifically for the Flexit L7X/S7X (VG700) heat recovery ventilation system. The set includes two high-efficiency filters that work together to clean both incoming supply air and extracted exhaust air. Available in the F7+F7 configuration, this set delivers premium filtration performance for residential and commercial installations where superior indoor air quality is required.
Understanding filter efficiency helps you choose the right set for your environment:
Choose the F7+F7 set when indoor air purity is your top priority and you want comprehensive protection against fine particulate matter.
Our Flexit L7X/S7X filter sets feature DEEP PLEAT construction that maximizes filtration surface area within the standard frame dimensions. This advanced pleating method delivers superior performance compared to conventional flat-panel designs.
These Flexit HRV filters are manufactured using ECO Green materials that balance environmental responsibility with filtration performance. The moisture-resistant cardboard frame is recyclable, and the filter media is designed for efficient particle capture without excessive material use. This practical approach to sustainability delivers the air quality you need while minimizing environmental impact.
For optimal performance, replace your Flexit L7X/S7X filters two to three times per year, depending on local air quality and system usage patterns. Regular replacement maintains cleaner indoor air, protects efficient airflow through the ventilation system, and reduces mechanical strain on the HRV unit. If you live in an urban area or near construction sites, consider replacing filters more frequently.
Replace filters every 4 to 6 months, or 2 to 3 times per year based on air quality conditions.
M5 captures particles down to 10 micrometers, while F7 captures ultra-fine particles down to 0.3 micrometers for superior air quality.
Yes, this set is specifically designed for Flexit L7X/S7X (VG700) recuperators with filter dimensions 394x223x250/5 + 394x223x20 mm.
The set includes two filters in the F7+F7 configuration for complete system filtration.
These are high-quality compatible aftermarket replacement filters that meet or exceed original specifications.
Explore our full range of Flexit HRV Filters for other Flexit ventilation models, or browse our complete selection of recuperator filters for all major heat recovery ventilation brands.
Buy Flexit L7X/S7X (VG700) Filter Set (394x223x250/5 + 394x223x20) online today. Ensure optimal air quality in your ventilation system with this precision-engineered replacement filter set.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |