- Delivery: 4-8 days.
Replacement filter set for Brink Renovent Excellent 180 and Renovent Small systems. G4+G4 economical configuration, 290x136x5 mm dimensions, moisture-resistant construction. Complete set includes both supply and extract filters.
Date sheet
Buy Brink Renovent Excellent 180 / Renovent Small filter set (290x136x5) online — economical G4+G4 configuration engineered for balanced ventilation and long service life.
This replacement filter set is specifically designed for Brink Renovent Excellent 180 and Renovent Small heat recovery ventilation systems. The set ensures continuous filtration of both incoming supply air and outgoing extract air, maintaining indoor air quality and protecting the recuperator heat exchanger from particle buildup. This economical G4+G4 configuration is ideal for residential environments with standard air quality requirements, offering reliable protection at a cost-effective price point.
Choosing the right filter class depends on your indoor air quality needs and local environment:
These Brink filters incorporate DEEP PLEAT manufacturing technology, which creates precisely engineered pleats that maximize the filtering surface area within the compact 290x136x5 mm dimensions. This advanced construction delivers superior airflow characteristics and extended service intervals compared to standard flat-panel designs.
These filters are manufactured using ECO Green synthetic media, which combines effective filtration performance with environmental responsibility. The moisture-resistant cardboard frame provides structural integrity without relying on metal components, making the filters easier to dispose of responsibly at end-of-life. Manufacturing in Lithuania ensures shorter transportation distances for EU customers, reducing carbon footprint associated with logistics.
For optimal system performance and indoor air quality, replace both filters every 6 months under normal residential conditions. Properties located near busy roads, industrial areas, or agricultural zones may require more frequent replacement every 3-4 months. Monitor pressure drop indicators on your Brink unit if available, or visually inspect filters quarterly. Clogged filters reduce ventilation effectiveness and increase energy consumption as the system works harder to maintain airflow.
Are these filters compatible with both Brink Renovent Excellent 180 and Renovent Small models?
Yes, both recuperator models use the same 290x136x5 mm filter dimensions. This set is confirmed compatible with both systems.
What is the difference between G4+G4 and F7+G4 filter sets?
The G4+G4 economical set uses G4 class filters for both supply and extract positions, providing standard protection. The F7+G4 configuration uses a higher-performance F7 filter for incoming supply air, capturing finer particles including allergens and combustion residues, while maintaining a G4 filter for outgoing extract air.
How often should I replace these Brink filters?
Replace every 6 months under typical residential use. Increase frequency to every 3-4 months in environments with higher dust levels, nearby construction, or heavy traffic exposure.
Can I install these filters myself?
Yes, filter replacement in Brink Renovent systems is designed for user-level maintenance. Consult your unit manual for specific access panel location and installation orientation. Ensure filters are seated correctly to prevent air bypass.
Are these original Brink filters or aftermarket replacements?
These are high-quality aftermarket replacement filters manufactured to match original specifications. They provide equivalent performance and compatibility at competitive pricing with fast EU delivery.
Explore our complete range of Brink recuperator filters at filters1.eu. We stock filter sets for all major Brink models including Renovent Excellent, Renovent Sky, Renovent HR, and Elan series. All filter sets ship quickly across Ireland, UK, Netherlands, Belgium, Finland, Sweden, Denmark, Austria, Switzerland and throughout the EU.
Order your Brink Renovent Excellent 180 / Renovent Small filter set (290x136x5) today for fast EU delivery — maintain optimal ventilation performance and indoor air quality with reliable replacement filters engineered for precise compatibility.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |
Buy Brink Renovent Excellent 180 / Renovent Small filter set (290x136x5) online — economical G4+G4 configuration engineered for balanced ventilation and long service life.
This replacement filter set is specifically designed for Brink Renovent Excellent 180 and Renovent Small heat recovery ventilation systems. The set ensures continuous filtration of both incoming supply air and outgoing extract air, maintaining indoor air quality and protecting the recuperator heat exchanger from particle buildup. This economical G4+G4 configuration is ideal for residential environments with standard air quality requirements, offering reliable protection at a cost-effective price point.
Choosing the right filter class depends on your indoor air quality needs and local environment:
These Brink filters incorporate DEEP PLEAT manufacturing technology, which creates precisely engineered pleats that maximize the filtering surface area within the compact 290x136x5 mm dimensions. This advanced construction delivers superior airflow characteristics and extended service intervals compared to standard flat-panel designs.
These filters are manufactured using ECO Green synthetic media, which combines effective filtration performance with environmental responsibility. The moisture-resistant cardboard frame provides structural integrity without relying on metal components, making the filters easier to dispose of responsibly at end-of-life. Manufacturing in Lithuania ensures shorter transportation distances for EU customers, reducing carbon footprint associated with logistics.
For optimal system performance and indoor air quality, replace both filters every 6 months under normal residential conditions. Properties located near busy roads, industrial areas, or agricultural zones may require more frequent replacement every 3-4 months. Monitor pressure drop indicators on your Brink unit if available, or visually inspect filters quarterly. Clogged filters reduce ventilation effectiveness and increase energy consumption as the system works harder to maintain airflow.
Are these filters compatible with both Brink Renovent Excellent 180 and Renovent Small models?
Yes, both recuperator models use the same 290x136x5 mm filter dimensions. This set is confirmed compatible with both systems.
What is the difference between G4+G4 and F7+G4 filter sets?
The G4+G4 economical set uses G4 class filters for both supply and extract positions, providing standard protection. The F7+G4 configuration uses a higher-performance F7 filter for incoming supply air, capturing finer particles including allergens and combustion residues, while maintaining a G4 filter for outgoing extract air.
How often should I replace these Brink filters?
Replace every 6 months under typical residential use. Increase frequency to every 3-4 months in environments with higher dust levels, nearby construction, or heavy traffic exposure.
Can I install these filters myself?
Yes, filter replacement in Brink Renovent systems is designed for user-level maintenance. Consult your unit manual for specific access panel location and installation orientation. Ensure filters are seated correctly to prevent air bypass.
Are these original Brink filters or aftermarket replacements?
These are high-quality aftermarket replacement filters manufactured to match original specifications. They provide equivalent performance and compatibility at competitive pricing with fast EU delivery.
Explore our complete range of Brink recuperator filters at filters1.eu. We stock filter sets for all major Brink models including Renovent Excellent, Renovent Sky, Renovent HR, and Elan series. All filter sets ship quickly across Ireland, UK, Netherlands, Belgium, Finland, Sweden, Denmark, Austria, Switzerland and throughout the EU.
Order your Brink Renovent Excellent 180 / Renovent Small filter set (290x136x5) today for fast EU delivery — maintain optimal ventilation performance and indoor air quality with reliable replacement filters engineered for precise compatibility.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |