Domekt R 150 F C8 Filter Set (225X172X46) for Komfovent recuperators. Available in Standard M5+M5 (ePM10 55%) or Effective F7+M5 (ePM1 65%) variants. Complete set with both supply and extract filters. Moisture-resistant construction with ECO Green materials. Compliant with ISO 16890 and EN 779:2012 standards.
Fast EU delivery. Perfect fit for Komfovent Domekt R 150 F C8 units.
Date sheet
Buy Domekt R 150 F C8 Filter Set (225X172X46) online. Complete replacement filter set for Komfovent Domekt R 150 F C8 recuperators with fast EU delivery and confirmed compatibility.
The Domekt R 150 F C8 Filter Set (225X172X46) is a complete replacement filter solution designed for Komfovent Domekt R 150 F C8 heat recovery ventilation units. This set filters both incoming supply air and outgoing extract air, helping maintain clean indoor air quality and protecting the recuperator from dust buildup. The set is available in two variants: the Standard M5+M5 set for general residential use and the Effective F7+M5 set for enhanced fine particle filtration in urban or high-pollution environments.
Understanding filter classes helps you choose the right set for your air quality needs:
Choose the Effective F7+M5 set if you live in a city, near roads, or want maximum protection against fine particles. Choose the Standard M5+M5 set for rural areas or standard residential ventilation needs.
These Domekt R 150 F C8 replacement filters feature DEEP PLEAT construction, which increases the filter surface area while maintaining compact dimensions. This technology delivers consistent performance throughout the filter's service life.
The filter media uses ECO Green materials that combine effective filtration with practical sustainability. The moisture-resistant cardboard frame withstands typical HRV operating conditions while maintaining structural integrity. This approach delivers reliable performance without unnecessary complexity.
Replace your Domekt R 150 F C8 filters two to three times per year, depending on outdoor air quality and system usage. Regular replacement maintains clean indoor air, protects airflow efficiency, and reduces strain on the recuperator unit. Set a reminder based on your local conditions and monitor filter condition during seasonal changes.
Replace filters two to three times per year for optimal performance and air quality.
M5 filters capture medium particles around 10 micrometers, while F7 filters capture ultra-fine particles down to 0.3 micrometers.
Yes, these filters are designed specifically for the Komfovent Domekt R 150 F C8 recuperator with exact 225 x 172 x 46 mm dimensions.
Each set includes two filters: one for supply air and one for extract air.
These are high-quality compatible replacement filters manufactured to meet original specifications and European standards.
For more compatible options, explore our full range of Komfovent Domekt filters or browse all recuperator filters available for fast EU delivery.
Buy Domekt R 150 F C8 Filter Set (225X172X46) online. Order today for fast EU delivery and keep your Komfovent recuperator running efficiently.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |
Buy Domekt R 150 F C8 Filter Set (225X172X46) online. Complete replacement filter set for Komfovent Domekt R 150 F C8 recuperators with fast EU delivery and confirmed compatibility.
The Domekt R 150 F C8 Filter Set (225X172X46) is a complete replacement filter solution designed for Komfovent Domekt R 150 F C8 heat recovery ventilation units. This set filters both incoming supply air and outgoing extract air, helping maintain clean indoor air quality and protecting the recuperator from dust buildup. The set is available in two variants: the Standard M5+M5 set for general residential use and the Effective F7+M5 set for enhanced fine particle filtration in urban or high-pollution environments.
Understanding filter classes helps you choose the right set for your air quality needs:
Choose the Effective F7+M5 set if you live in a city, near roads, or want maximum protection against fine particles. Choose the Standard M5+M5 set for rural areas or standard residential ventilation needs.
These Domekt R 150 F C8 replacement filters feature DEEP PLEAT construction, which increases the filter surface area while maintaining compact dimensions. This technology delivers consistent performance throughout the filter's service life.
The filter media uses ECO Green materials that combine effective filtration with practical sustainability. The moisture-resistant cardboard frame withstands typical HRV operating conditions while maintaining structural integrity. This approach delivers reliable performance without unnecessary complexity.
Replace your Domekt R 150 F C8 filters two to three times per year, depending on outdoor air quality and system usage. Regular replacement maintains clean indoor air, protects airflow efficiency, and reduces strain on the recuperator unit. Set a reminder based on your local conditions and monitor filter condition during seasonal changes.
Replace filters two to three times per year for optimal performance and air quality.
M5 filters capture medium particles around 10 micrometers, while F7 filters capture ultra-fine particles down to 0.3 micrometers.
Yes, these filters are designed specifically for the Komfovent Domekt R 150 F C8 recuperator with exact 225 x 172 x 46 mm dimensions.
Each set includes two filters: one for supply air and one for extract air.
These are high-quality compatible replacement filters manufactured to meet original specifications and European standards.
For more compatible options, explore our full range of Komfovent Domekt filters or browse all recuperator filters available for fast EU delivery.
Buy Domekt R 150 F C8 Filter Set (225X172X46) online. Order today for fast EU delivery and keep your Komfovent recuperator running efficiently.
| Filter Type / EN 779 | ISO 16890 | >10 µm | PM10 | PM2.5 | PM1 | Gas/LOI | Typical Pollutants |
|---|---|---|---|---|---|---|---|
| G1 | ISO Coarse | ~40% | <10% | ~0% | ~0% | Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc. | |
| G2 | ISO Coarse | ~50% | <15% | ~0% | ~0% | Sawdust, hair, large fabric shreds, paint chips, surface rust particles. | |
| G3 | ISO Coarse | ~60% | <25% | ~5% | ~0% | Larger household dust, lint, animal hair, some airborne pollen. | |
| G4 | ISO Coarse | 65-75% | 25-35% | 10-15% | <5% | Larger pollen grains, soil and sand impurities, textile fibers. | |
| M5 | ISO ePM10 ≥50% | ~80% | 50–65% | 20–30% | 10–15% | Most pollen, mold spores, pet dander, typical house dust. | |
| M6 | ISO ePM10 (60–80%) | ~90% | 65–80% | 30–45% | 15–25% | Construction material dust, concrete and cement powders, ash and other friable material particles. | |
| F7 | ISO ePM2.5 (50–65%) | >90% | 75–90% | 50–65% | 30–45% | Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke. | |
| F8 | ISO ePM2.5 (65–80%) | >95% | 85-95% | 65–80% | 45-60% | Fine fungal spores, airborne pollutant aerosols and other fine solid particles. | |
| F9 | ISO ePM1 (80-95 %) | >95% | >95% | >90% | 80-95% | Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere. |